Communication parameters, Appendix – LG 26LC5 User Manual

Page 112

Advertising
background image

110

APPENDIX

APPENDIX

01. Power

k

a

0 ~ 1

02. Input Select

k

b Refer to p. 111

03. Aspect Ratio

k

c Refer to p. 111

04. Screen Mute

k

d

0 ~ 1

05. Volume Mute

k

e

0 ~ 1

06. Volume Control

k

f

0 ~ 64

07. Contrast

k

g

0 ~ 64

08. Brightness

k

h

0 ~ 64

09. Colour

k

i

0 ~ 64

10. Tint

k

j

0 ~ 64

11. Sharpness

k

k

0 ~ 64

12. OSD Select

k

l

0 ~ 1

13. Remote control lock mode k m

0

~ 1

14. Balance

k

t

0 ~ 64

15. Colour Temperature

k u

0

~ 3

16. Red Adjustment

k

v

0 ~ 50

17. Green Adjustment

k

w

0 ~ 50

18. Blue Adjustment

k

$

0 ~ 50

19. Abnormal Status

k

z

0 ~ 9

20. ISM Method

j

p Refer to p. 113

21. Low Power

j

q

0 ~ 1

22. Auto Configure

j

u

1

23. Channel Select Command m

a

Refer to p. 114

24. Send IR Code

m

c Key Code

25. Input select (Main)

x

b

Refer to p. 114

Communication Parameters

A

Baud rate : 9600 bps (UART)

A

Data length : 8 bits

A

Parity : None

A

Stop bit : 1 bit

A

Communication code : ASCII code

A

Use a crossed (reverse) cable.

Transmission

* [Command 1] : First command to control the set.

(j, k, m or x)

* [Command 2] : Second command to control the set.
* [Set ID]

: You can adjust the set ID to choose

desired monitor ID number in option
menu.
Adjustment range is 1 ~ 99.
When selecting Set ID ‘0’, every
connected the set is controlled.
Set ID is indicated as decimal (1~99) on
menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.

* [DATA]

: To transmit command data.

Transmit ‘FF’ data to read status of
command.

* [Cr] :

Carriage

Return

ASCII code ‘0x0D’

* [ ]

: ASCII code ‘space (0x20)’

[Command1][Command2][ ][Set ID][ ][Data][Cr]

OK Acknowledgement

* The set transmits ACK (acknowledgement) based on

this format when receiving normal data. At this time, if
the data is data read mode, it indicates present status
data. If the data is data write mode, it returns the
data of the PC computer.

[Command2][ ][Set ID][ ][OK][Data][x]

Error Acknowledgement

* The set transmits ACK (acknowledgement) based on

this format when receiving abnormal data from
non-viable functions or communication errors.

[Command2][ ][Set ID][ ][NG][Data][x]

Transmission / Receiving Protocol

Command Reference List

* When setting the 19 ~ 25, a menu doesn’t display on screen.

Data 1: Illegal Code

2: not support function
3: Wait more time

COMMAND

1

COMMAND

2

DATA

(Hexadecimal)

Advertising
This manual is related to the following products: