Linksys EF2H16 User Manual

Page 9

Advertising
background image

10/100 Hubs

The following illustration is an example of how to connect two rack-mount-
able EtherFast II 10/100 Hubs together using fiber optic cabling. Notice that
both hubs are equipped with 100BaseFX 1-Port Distance Extender modules.
The distance extender modules allow data to be sent up to 208 meters (672
feet).

For a full explanation of fiber optic cabling distance rules, see the chart on
page 12.

13

Instant EtherFast II Series

When using fiber, the noise loss has to be calculated. Also, always use the
same type of fiber connector (SC or ST) for your fiber cables. If you are
using ST-type connectors and you introduce an SC-type connector module, an
SC to ST converter has to be obtained, or the ST connector may be replaced
by an SC Connector

The following table shows the distance limitation when connecting the
Linksys Fiber modules:

12

N

No

otte

e:: Changing connectors should be done professionally,

using the proper tools. If you have never worked with fiber
cabling, seek the help of an experienced professional.

Maximum distance

0f 208 meters

Distance (meters/ft) Cable type

Module in Hub A

Module in hub B

208/672

Multi-Mode

EF2HSC or EF2HST,

EF2HSC, EF2HST

62.5/125uM

SC or ST Type 100BaseFX SC or ST Type

Fiber Optic Cable

Fiber Distance Extender Fiber Transceiver Module

412/1330

Multi-Mode

EF2HSC or EF2HST EF2HSC, EF2HST

(Half Duplex)

62.5/125uM

SC or ST Type

SC or ST Type

Fiber Optic Cable

Fiber Distance Extender Fiber Distance Extender