La Crosse Technology INFRASCAN IR 101 User Manual

Page 7

Advertising
background image

7

Fastening the Infrared Thermometer

A soft-sided pouch with a belt loop and a quick release neck strap are included with
the infrared thermometer. To attach the infrared thermometer to the neck strap
simply insert the clip of the neck strap into the buckle end of the thermometer until it
clicks. To release, press both sides of the clip on the neck strap and pull the buckle
end until it is free.

Technical Information

1. Accuracy: The larger of the two values given is applicable in each case.
2. Distance to measuring spot size: The parameter D : S characterizes the size

of the measuring spot in proportion to the distance between the object to be
measured and the Infrared Thermometer. For example, with a ratio of 6 : 1
and a distance of 12 inches, the monitoring area will have a diameter of 2
inches.









Range

:

-5

°F to 575°F

Resolution

: 0.1

°F

Accuracy :

± 1°F

Unit

:

°F or °C

Distance to measuring spot size D:S

:

6:1

Ambient temperature range

:

32

°F to 104°F

Emission

factor

: 0.95

Power

supply

: 4

x

LR44

button cell
batteries

Battery life (approx.)

:

2000

measurements

(depending on the
usage)

Dimensions (L”xW”xH”)

:

2.25” x 1” x 4”

S