Appliance specifications – Lennox Hearth B-Vent Elite LBV-3824MP-H User Manual

Page 4

Advertising
background image

4

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Venting

Gas Vent Rule – Gas vent caps are not permit-
ted within 8 feet (2.4 mm) of a vertical wall or
similar obstruction. Gas vent caps that are
located 8' or more from a portion of a building
which extends at an angle greater than 45

°

upward from the horizontal may terminate in
accordance with

Table 1 (Figure 3), provided

that in no case shall any discharge opening on
the cap be less than 2' (610 mm) horizontally
from the roof surface (National Fuel Gas Code
ANSI Z223.1 (NFPA 54) 7.6.2) (CAN/CGA
B149).

CLEARANCES

Minimum clearance to combustibles for the ap-
pliance is as follows: sides and back -

¹⁄₂" (13

mm), floor - 0" (0 mm), adjacent wall - 0" (0 mm),
ceiling - 37

¹⁄₂" (953 mm).

APPLIANCE SPECIFICATIONS

Figure 2

Table 1

Note: Venting terminals shall not be recessed
into a wall or siding.

Flat to 6/12

1' 0"

0.3

Over 7/12 to 9/12

2' 0"

0.6

Over 10/12 to 12/12

4' 0"

1.2

Over 13/12 to 16/12

6' 0"

1.8

Over 17/12 to 21/12

8' 0"

2.4

Roof Slope

Minimum Height

from Roof to Lowest

Discharge Opening

Feet

Meters

Figure 3

Roof Pitch is X/12

12

X

Minimum Height from Roof
to Lowest Discharge Opening

25

⁵⁄₈"

Gas Line

Access

Left Side View

Right Side View

49

³⁄₄"

25

⁵⁄₈"

Top View

Gas Line

Access

Junction

Box

3

¹⁄₂"

7

¹⁄₄"

10

¹⁄₂"

6

¹⁄₂"

3

¹⁄₄"

15

¹⁄₂"

11"

Combustion

Air Inlet

Front View

11

¹⁄₂"

3824 - 38"

4324 - 43

¹⁄₂"

24

⁵⁄₈"

8"

8"

B-Vent

9

³⁄₄"

25

⁵⁄₈"

44

¹⁄₈"

12

⁷⁄₁₆"

44

¹⁄₈"

3824 - 5"

4324 - 4

³⁄₈"

Electrical Outlet

3824 - 26

⁵⁄₁₆"

4324 - 31

¹⁄₁₆"

3824 - 48"

4324 - 52

³⁄₄"

3824 -

⁵⁄₈"

4324 -

¹⁄₂"

49

³⁄₄"

3824 - 48"

4324 - 52

³⁄₄"