Filters – Lennox International Inc. 80UHG User Manual

Page 4

Advertising
background image

Page 4

6 - White Rodgers 36E Gas Valve - Switch gas valve lever

to OFF. See figure 2.

Honeywell VR8205 Gas Valve - Turn knob on gas valve
clockwise

to OFF. Do not force. See figure 3.

WHITE RODGERS 36E SERIES GAS VALVE

GAS VALVE SHOWN IN OFF POSITION

FIGURE 2

ON

OFF

HONEYWELL VR8205 SERIES GAS VALVE

GAS VALVE SHOWN IN OFF POSITION

FIGURE 3

7 - Wait five (5) minutes to clear out any gas. If you then

smell gas, STOP! Immediately call your gas supplier

from a neighbor's phone. Follow the gas supplier's

instructions. If you do not smell gas go to next step.

8 - White Rodgers 36E Gas Valve - Switch gas valve lever

to ON.

Honeywell VR8205 Gas Valve - Turn knob on gas
valve counterclockwise

to ON. Do not force.

9 - Replace the control access panel.
10 - Turn on all electrical power to unit.
11 - Set thermostat to desired setting.

NOTE – When unit is initially started, steps 1 through 11
may need to be repeated to purge air from gas line.

12 - If the appliance still will not operate, follow the

instructions To Turn Off Gas To Unit" and call your

service technician or gas supplier.

To Turn Off Gas To Unit
1 - Set thermostat to lowest setting.
2 - Turn off all electrical power to unit if service is to be

performed.

3 - Remove the control access panel.
4 - Switch lever on White Rodgers gas valve to OFF; turn

knob on Honeywell valve clockwise

to OFF. Do not

force.

5 - Replace the control access panel.

Filters

80UHG series units are equipped with external filters

which should be inspected monthly and replaced

when necessary to assure proper furnace operation.

See table 1 for filter sizes. Replacement filters used

with 80UHG-40/60/75 units must have a minimum veĆ

locity rating of 400 FPM. Replacement filters used

with 80UHG-100/120 units require a minimum velocĆ

ity rating of 625 FPM. Figures 4 and 5 show possible

filter locations.

TABLE 1

MODEL NUMBER

FILTER SIZE

MODEL NUMBER

1 FILTER

80UHG-45/60/75

16 in. X 20 in. X 1 in.

80UHG-100/120/140

20 in. X 20 in. X 1 in.

UPFLOW FURNACE

BOTTOM RETURN AIR

FIGURE 4