PRECISION TIG 275

TROUBLESHOOTING & REPAIR

T1 MAIN TRANSFORMER TEST (continued)

Table F.3 - T1 Transformer Voltages

TEST POINTS

ACCEPTABLE VOLTAGES

SECONDARY WINDINGS

PLUG J11 PIN 8 (LEAD W209)

TO

PLUG J11 PIN 16 (LEAD R210)

PLUG J11 PIN 7 (LEAD #201)

TO

PLUG J11 PIN 15 (LEAD #204)

X1 TO X2

PRIMARY WINDINGS

H1 TO H2
H1 TO H3
H1 TO H4

SECONDARY VOLTAGES

20 VAC

18VAC

78 VAC

PRIMARY VOLTAGES

208 VAC
230 VAC
460 VAC

NOTE: If the input voltages vary, the secondary voltages will vary accordingly.
Based on 208/230/460 models. For other voltage models refer to appropriate Wiring Diagram.