Symptoms, The machine is dead, no output, no fan, Theory of operation – Lincoln Electric V155-S User Manual

Page 36: Caution

Advertising
background image

OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

The line circuit breaker trips

when power switch is “ON”

1. Input power Bridge is shorted.
2. Failed Electrolytic Capacitors.
3. Failed Inverter IGBTʼs.

1. Perform the Input Board

Resistance Test

.

2. Perform the Inverter Board

Resistance Test

.

The machine is dead, no output,

no fan

1. No input power on line.
2. Line Switch failure.
3. Defective Input Board.
4. Defective Inverter Board

1. Restore correct Input power
2. Replace Line switch.
3. Perform Input Board Voltage

Test.

4. Perform Inverter Board

Voltage Test

.

The GREEN LED is “ON” but

there is no output And yellow

thermal overload LED is “ON”

1. Thermal Protection has

tripped.

2. Logic Circuit Error on Control

Board.

3. ARFU System Damage on the

Input Board

1. Check Fan and Thermal

Protection Circuits.

2. Perform Input Board

Resistance

and Input Board

Voltage Tests

3. The Control Board may be

faulty. Replace.

THEORY OF OPERATION

F-4

F-4

INVERTEC® V155-S

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

The YELLOW LED is “ON” and

the RED and GREEN LEDʼs blink

alternately

1. The machine is unable to cool

itself.

1. Turn the Power Switch OFF and

wait several minutes for the

machine to cool. Turn the Power

Switch back ON and check for

proper fan operation.