CARE AND OPERATION

PAGE 14

GLASS
The Glass is a super heat resistant ceramic that withstands
continuous temperatures up to 1390° F. This temperature
is well beyond the temperatures in which you operate your
stove.

This unit is designed to provide a flow of air over the inside
of the glass, where along with high heat helps keep it clean.
When operating the stove on low for extended periods of
time, the glass may get dirty. A short, hot fire (15 - 20 min-
utes) will help clean off much of the normal buildup (see
Troubleshooting, page 19). A commercial glass cleaner
designed for stoves is recommended for cleaning.

The glass should be cleaned thoroughly with glass
cleaner and a soft cloth
BEFORE the stove is burned.

PRIMARY AIR CONTROL

The Model 1900HT-M has one combustion air control

located under the ash lip.

Start-up: To provide sufficient combustion air to achieve

a clean burn as quickly as possible, the 1900HT-M has

the ability to supplement its primary air with extra "Start-

Up" air. This is achieved by pulling the air control rod all

the way out, and should only be adjusted to this setting

when starting a fire, when refueling or otherwise for short

duration’s only.

CAUTION: OPERATION WITH PRIMARY AIR CON-

TROL IN "START-UP" POSITION (PULLED ALL THE

WAY OUT) FOR EXTENDED PERIODS, WASTES

FUEL AND CAN CAUSE DANGEROUS OVERFIRING

CONDITIONS. NEVER LEAVE STOVE UNATTENDED

ON HIGH SETTINGS.


Adjusting Burn Rate: The primary air control handle

can be pulled out to the open position for higher tem-

peratures and moved in to a more closed position for

lower temperatures.


IMPORTANT: Push air control all the way in (closed)

before pulling rod out to set desired burn rate. This

clears the high burn control plate so it is not left open.

Generally, you will want to set the air control somewhere

in the low or medium range.

Low Burn - (approx. 9,000-13,000 Btu/hr.).

Pull control handle out approx. 3/4”.


Medium - Burn (approx. 13,000-16,000 Btu/hr.). Pull
control handle out approx. 1 1/2”.


Medium-High Burn (approx. 16,000-25,000 Btu/hr.).
Pull control handle out approx. 2 1/2”, until small click is felt.

High Burn (Maximum – approx. 44,000 Btu/hr.)

Pull control handle out to its full extended position.

WARNING: OPERATING STOVE ON HIGH FOR EX-

TENDED PERIODS WASTES FUEL, AND WILL

CAUSE A WHITE BUILD-UP (HAZE) ON GLASS AND

CAN CAUSE DANGEROUS OVERFIRING CONDI-

TIONS. NEVER LEAVE STOVE UNATTENDED ON

HIGH.

PROVIDE ADEQUATE AIR FOR COMBUSTION

In well insulated and weather tight homes, it may be diffi-

cult to establish a good draft up your chimney. The poor

draft is caused by a shortage of air in the house. To pro-

vide the needed air, crack a window on the windward

side of the house. In some cases, you may want to duct

air directly from the outside to your firebox (See Outside

Combustion Air, page 7), or to a nearby floor or wall vent.

USE CONTROL SETTINGS THAT WORK FOR YOU

The fuel, the amount of heat you want, the type of instal-

lation you have and how long you wish the fire to burn

are all variables that will affect the control setting. The

same control settings in a variety of installations will pro-

duce different results.

Familiarize yourself with your stove by trying different

settings so you can learn how much heat to expect and

how long the fire will burn. It may take a week or two to

learn but your patience will be rewarded by the warmth

and pleasant satisfaction that only a wood fire can pro-

vide.

Low Burn
Control Plate
Positions

Medium-Low Burn -
Control Plate Positions

Start-up
Control Plate
Positions

Medium High Burn
- Control Plate Posi-
tions

High Burn - Control
Plate Positions