WIRING INSTRUCTIONS (OUTSIDE OF HOUSING)

Wiring Color Code Power and Control Inputs

POWER

1

Camera Power (24 VAC)

Red

2

Camera Power (24 VAC)

Orange

3

Heater and Blower Power (24 VAC)

Yellow

4

Heater and Blower Power (24 VAC)

Green

CONTROL

1

Alarm 1

Blue

2

Alarm 2

Violet

3

Alarm 3

Gray

4

Common

White

(2) 40Va power transformers are provided with all outdoor units.
The unit is set up with (2) individual power inputs:

1. Accessory Power (yellow and green wire)
2. Camera Power (red and orange)

If you wish to provide a single power transformer it is
recommended that:
1. Be certain that you know the total power consumption of

the housing Heater (25 watts) + Blower (1 watt) + camera
pan/tilt (25 watts).

2. Check the supplied wiring chart (see below) to be sure that

you have the proper gauge wire for the distance that you
intend to run your power wires.

3. Bring power to the 3 and 4 position of the power connector

(yellow and green wire).

4. Jumper from the 1

st

position to the 3

rd

position and from

the 2

nd

position to the 4

th

position of the terminal block.

Be careful not to short between the yellow and green wires.

22

250
120

89
65
44
35
29
25
31
19
17
16
14
13
12
11
11
10

9
9
8

20

400
180
141

90
70
56
47
40
34
31
28
25
23
21
20
18
17
16
15
14
14

18

600
300
225
130
112

90
75
64
55
50
45
41
37
34
32
30
28
26
25
23
22

16

960
480
358
225
179
143
119
102

85
79
71
65
59
55
51
47
44
42
39
37
35

14

-

800
571
350
285
228
190
163
140
126
114
103

95
87
81
76
71
67
63
60
57

12

-

1300

905
525
452
362
301
258
215
201
181
164
150
139
129
120
113
106
100

95
90

10

-
-

1440

830
720
576
480
411
340
320
288
261
240
221
205
192
180
169
160
151
144

5.5

10
20
30
40
50
60
70
80
90

100
110
120
130
140
150
160
170
180
190
200

Maximum distance from transformer to load

Total vA

consumed

Wire Gauge

24V AC Wiring Distances

The following are the recommended maximum distances for 24 VAC

with a 10% voltage drop (10% is generally the maximum allowable

voltage drop for AC powered devices).

Maximum distance from transformer to load

NOTE: The total power consumption for the heater

and blower, PLUS the camera you choose,
need to be added together.

In this example, a 60VA AC24V is required.