2 4 V D C / 1 1 5 V A C P o w e r I n v e r t e r

The AC power inverter is only 115V. The AC power inverter uses battery

power, so the batteries may require more frequent charging.

WARNING

Remove ALL fuses from the cables before connecting ANY

cables to the batteries or switch. Make sure all the DC

connections are tight (torque to 9-10 ft-lbs, 11.7-13 Nm).

Loose connections overheat and could result in a potential

hazard.

Check the wiring for your batteries and charger.

Make sure the proper voltage fuse is installed in each fuse holder.
Each fuse is labeled as 20A or 30A.
The batteries are connected with a 30 Amp fuse
BAT2 has a 20 Amp fuse from it to the terminal block.

Power Options 4-3

Green Wire
Ground to Station Floor

Black
Wire (-) to
Terminal
Block

Red Stripe Wire
to Terminal

30 Amp
Fuse Jumper
Connect, F2

BAT 1

BAT 2

Red Wire to
Inverter

20 Amp
Fuse, F1

Red Wire to
Terminal Block

Advertising