7 - ENG

• Do not operate the product when

fatigued or under the influence of alco-

hol or drugs. Stay alert at all times.

• Never defeat the safety fea­

tures of this prod uct.

• Equip area of operation with

a fire extinguisher.

• Do not op er ate machine with miss-

ing, broken, or un au tho rized parts.

• Never stand on the compressor.

HAZARD

RISk OF FALLING

WHAT CAN HAPPEN

HOW TO PREVENT IT

• A portable compressor can

fall from a table, workbench,

or roof causing damage to

the compressor and could

result in serious injury or

death to the operator.

• Always operate compressor in a stable

secure position to prevent accidental

movement of the unit. Never operate

compressor on a roof or other elevated

position. Use additional air hose to

reach high

locations.

HAZARD

RISk FROM NOISE

WHAT CAN HAPPEN

HOW TO PREVENT IT

• Under some conditions

and duration of use, noise

from this product may con-

tribute to hearing loss.

• Always wear certified safety equipment:

ANSI S12.6 (S3.19) hearing protection.

SAVE THESE INSTRUCTIONS

FOR FUTURE USE

SPECIFICATIONS

Model No.

C2002

Bore

1.875" (47.6 mm)

Stroke

1.250" (31.8 mm)

Voltage/Hz-Single Phase

120/60

Minimum Branch Circuit Requirement

15 amps

Fuse Type

Time Delay

Air Tank Capacity

6 Gallons (22.7 liters)

Approximate Cut-in Pressure

120 psig

Approximate Cut-out Pressure

150 psig

SCFM @ 40 psig

3.5 *

SCFM @ 90 psig

2.6 *

*Tested per ISO 1217
Refer to Glossary for abbreviations.