FAULT CODES

The battery condition meter will flash fault codes when the controller system

detects an abnormal condition in the electrical system. All of the battery con-

dition meter LEDs will flash a number of times quickly, then pause, then flash

again. The battery condition meter will continue to flash the fault codes until

the problem is fixed. The table below identifies the individual fault codes. If

any of these fault codes persist, contact your authorized Pride Provider.

Fault
Codes

Probable Causes

Possible Solutions

1 Flash

The batteries need charging.
There is a bad connection to

the batteries.

Check the battery connections. If the

battery connections are good, then try

charging the batteries.

2 Flashes

There is a bad connection on

the left motor.

Check the left motor connections and

wiring harnesses.

3 Flashes

The left motor has a short to

the battery connection.

Contact your authorized Pride Pro-

vider.

4 Flashes

There is a bad connection on

the right motor.

Check the right motor connections

and wiring harnesses.

5 Flashes

The right motor has a short to a

battery connection.

Contact your authorized Pride Pro-

vider.

Scroll Left
to Right

The charge inhibit has been

activated.

Make sure that the battery charger is

not connected to the power base.

7 Flashes

There is a joystick fault.

Make sure the joystick is in the cen-

ter position and then power off and

on again.

8 Flashes

There is a control system fault.

Check power module and joystick

module connections and wiring.

9 Flashes

The park brakes have a bad

connection.

Check the left and right motor con-

nections and wiring.

10 Flashes

An excessive voltage has been

applied to the control system.

Check the battery connections.

Advertising