Porter-Cable C2025 User Manual

Page 15

Advertising
background image

15 - ENG

N000732

7. Replace hose and new hose clamp.
8. Perform the Break­in Procedure. See "Break­in Procedure" in the Operation

section.

TO REPLACE REGULATOR

1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance

section.

2. Unplug unit.
3. Using an adjustable wrench

Safety

Valve

Regulator

Manifold

Quick

Connects

Gauges

Hose

Clamp

remove the gauges, quick

connect, and safety valve from

the regulator manifold.

4. Remove the hose by removing

the hose clamp.

NOTE: The

hose clamp is not reusable.

You must purchase a new hose

clamp, purchase a standard

hose clamp at a local hardware

store.

5. Using an adjustable wrench

remove the regulator manifold.

6. Apply pipe sealant to new

regulator manifold and assemble, tighten with wrench.

7. Reapply pipe sealant to gauges, quick connect, and safety valve.
8. Reassemble all components in reverse order of removal. Make sure to orient

gauges to read correctly and use wrenches to tighten all components.

Advertising