Faqs – Panamax MAX 5510 User Manual

Page 15

Advertising
background image

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (283) 283-5901

My MAX

®

5510 power cable does not

reach the wall outlet. Can I use an

extension cord to make it reach?

Yes, but you must use only Panamax extension

cords to keep your warranty valid. Ask for Part

# GEC1410 (10 feet long) or

# P12X10NEMA5-15 (Premium Grade)

____

The provided coax or telephone jumper

cables are not long enough to reach my

equipment. Can I use other cables?

Yes, any length cable of the same type meets the

warranty requirements.

____

The 4 Amp, Isolation Transformer circuit

breaker continually trips. What is the

problem?

The four Isolation Transformer Outlets share the

500 VA Isolation Transformer for their power

source. The connected equipment plugged into

the four outlets is drawing more than 4 Amps

collectively, causing the circuit breaker to trip.

These four outlets are designed specifically for

low-current, digital source components. Check

to see if you have connected a high-current

amplifier or subwoofer to the Isolation

Transformer Outlets. If so, unplug the high-cur-

rent components and plug them into the High-

Current Outlet Bank.

____

The Isolation Transformer Outlets are not

switching ON or OFF with the MAX

®

5510.

How can I fix this?

These outlets may be set as either switched or

always-on outlets. The 3-position, Isolated

Outlet Turn-Off Delay switch on the back panel

controls this. Change the setting of this switch

from Always-On to a delayed setting. This will

allow the Isolation Transformer Outlets to

become Switched Outlets.

____

The MAX

®

5510 is ON but the Voltmeter

and Ammeter are not lit up. What is the

problem?

Check the Meter Light Dimmer control to see if

the lighting is turned ON or OFF. If the control

knob is turned OFF, turn it ON and continue

turning until you have reached the desired light

level. If the control knob is turned ON and there

is no light, turn the knob to maximum. If you

still have no light, call Panamax Customer

Service for help.

____

I connected the 5W Convenience Lamp

and the lamp will not work. What is the

problem?

1. Check to see if the bulb is burned-out.

2. If the bulb is good, if the unsafe voltage LED

is OFF and the light control knob is turned on

and the light is still not on, call Panamax

Customer Service for help .

____

The halogen light on the Convenience

Lamp is dead. What type of light do I

replace it with?

The halogen light must be replaced with a

12VDC, 5-Watt bulb or damage to lamp power

supply may occur. Use USHIO JC12V-5W/BA9S

or equivalent.

____

There is an audible buzz/hum coming

from my MAX

®

5510. What is the cause

of this and how do I make it go away?

This is the result of a DC Bias that is usually

introduced in your circuit by certain appliances-

most commonly lamps with High-Low dimmer

switches and some room heaters, which use

only half of the AC sine wave. These appliances

introduce a small DC bias placed on the AC sup-

ply. Some audio equipment- especially ampli-

fiers with toroidal power transformers- may react

unfavorably to this DC voltage, and buzz. The

MAX

®

5510 isolation transformer will remove

this waveform distortion and protect the loads

plugged into the isolated outlets. If the distortion

is bad, you may actually hear the MAX

®

5510

buzzing slightly as it works to correct the AC

power. The best way to stop the buzz is to find

the source of the disturbance (most likely a

quartz lamp) and plug it into a different branch

circuit. Panamax Technical Support will be glad

to help you if you have any questions about this.

FAQs

13

INS5510 REV. B