Serial interface control signals – Polycom ViewStation EX4000 User Manual

Page 48

Advertising
background image

Integrators’ Reference Manual for ViewStation EX, ViewStation FX, and VS4000

38

www.polycom.com

Serial Interface Control Signals

If you need to customize your V.35/RS-449/RS-530 interface, use
the signal information in Table 2-21 below in addition to the
information provided by your network equipment vendor.

Table 2-21. Serial Interface Control Signals

Signal
(Pin)

In/Out

Description

Configuration Option

ST
(TC/TT)

OUT

Send Timing
(clock)

Normal: falling edge sends data
Inverted: rising edge sends data

RT (RC)

IN

Receive
Timing (clock)

Normal: rising edge receives
data
Inverted: falling edge receives
data

RTS
(RTS)

OUT

Request To
Send

Normal: high is logic 1
Inverted: low is logic 1

DCD
(DCD)

IN

Data Carrier
Detect

Normal: high is logic 1
Inverted: low is logic 1

Filter: allow DCD to drop for 60
seconds before changing call
state

CTS
(CTS)

IN

Clear To Send

Normal: high is logic 1
Inverted: low is logic 1

DTR
(DTR)

OUT

Data Terminal
Ready

Normal: high is logic 1
Inverted: low is logic 1

On: signal remains high

a

a. If set to ON, inverted is not an option.

DSR
(DSR)

IN

Data Set
Ready

Normal: high is logic 1
Inverted: low is logic 1

Answer: Use DSR as a Ring-In
indication

b

b. DSR is not used as a ring-in indication if it is set to ANSWER in
the V.35 Advanced Setup screen.

Advertising