Serial interface control signals – Polycom ViewStation EX4000 User Manual
Page 48

Integrators’ Reference Manual for ViewStation EX, ViewStation FX, and VS4000
38
www.polycom.com
Serial Interface Control Signals
If you need to customize your V.35/RS-449/RS-530 interface, use
the signal information in Table 2-21 below in addition to the
information provided by your network equipment vendor.
Table 2-21. Serial Interface Control Signals
Signal
(Pin)
In/Out
Description
Configuration Option
ST
(TC/TT)
OUT
Send Timing
(clock)
Normal: falling edge sends data
Inverted: rising edge sends data
RT (RC)
IN
Receive
Timing (clock)
Normal: rising edge receives
data
Inverted: falling edge receives
data
RTS
(RTS)
OUT
Request To
Send
Normal: high is logic 1
Inverted: low is logic 1
DCD
(DCD)
IN
Data Carrier
Detect
Normal: high is logic 1
Inverted: low is logic 1
Filter: allow DCD to drop for 60
seconds before changing call
state
CTS
(CTS)
IN
Clear To Send
Normal: high is logic 1
Inverted: low is logic 1
DTR
(DTR)
OUT
Data Terminal
Ready
Normal: high is logic 1
Inverted: low is logic 1
On: signal remains high
a
a. If set to ON, inverted is not an option.
DSR
(DSR)
IN
Data Set
Ready
Normal: high is logic 1
Inverted: low is logic 1
Answer: Use DSR as a Ring-In
indication
b
b. DSR is not used as a ring-in indication if it is set to ANSWER in
the V.35 Advanced Setup screen.