A09770

6. Assemble the regulator and

orient as shown.

NOTE: Arrow indicates flow of

air. Make sure it is pointing in the

direction of air flow.

7. Reapply pipe sealant to outlet

pressure gauge and quick

connect.

8. Reassemble outlet pressure

gauge and quick connect. Orient

outlet pressure gauge to read

correctly. Tighten connect with

wrench.

To Replace Regulator

1. Release all air pressure from air

tank. See "To Drain Tank" in the

Maintenance section.

2. Unplug unit.
3. Using an adjustable wrench

remove the outlet pressure

gauge and quick connect from

the regulator.

4. Remove the regulator.
5. Apply pipe sealant tape to the

nipple on the standpipe.

Nipple

Outlet

Pressure

Gauge

Regulator

Quick

Connect

Arrow