Paxar FreshMarx System Monarch 9416 User Manual

Page 14

Advertising
background image

1

-10 Getting Started

C a l i b r a t i n g t h e S u p p l y

1.

Turn off the printer.

2.

Press and hold the FEED button while turning on

the printer.

3.

Release the FEED button after the indicator light

starts flashing ORANGE. The printer calibrates

the die cut sensor, measures the label length, and

prints the test labels.

4.

To resume normal printing, turn off the printer,

wait two seconds, then turn it back on again.
If the supply does not calibrate, make sure the

die cut sensor has not been accidentally

moved.

C h e c k i n g t h e D i e C u t S e n s o r

After loading supplies, make sure you did not

accidentally move the die cut sensor. The die cut

sensor senses and calibrates the supply. For your

supplies, make sure the middle of the square lens on

the die cut sensor the lines up with the arrow inside

the printer.

Sensor set for
Die Cut Supplies