Porter-Cable CPL55GH8W User Manual

Page 24

Advertising
background image

24-ENG

D26998

PROBLEM

CAUSE

CORRECTION

Knocking Noise. Possible defect in safety

valve.

Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.

Loose pulley.

Compressor or engine
mounting screws loose.

Loose flywheel.

Loose belt.

Check belt tension, see
Adjusting Belt Tension in the
Maintenance section

Carbon build-up in pump.

Have checked by a Trained
Service Technician.

Belt to tight.

Check belt tension, see
Adjusting Belt Tension in the
Maintenance section

Excessive belt
wear.

Loose belt.

Tight belt.

Loose pulley.

Have checked by a Trained
Service Technician.

Pulley misalignment.

See Motor Pulley/Flywheel
Alignment paragraph in the
Maintenance section.

Check belt tension, see
Adjusting Belt Tension in the
Maintenance section

Check belt tension, see
Adjusting Belt Tension in the
Maintenance section

Stiffener bar loose.

Check both nuts and tighten if
required.

Low oil level (compressor
or engine)

Maintain prescribed oil level.
Add oil.

Tighten pulley set screw, see
Parts manual for torque speci-
fications.

Tighten mounting screws,see
Parts manual for torque speci-
fications.

Tighten flywheel screw, see
Parts manual for torque speci-
fications.

Advertising