5-7

[Hardware zero signal type]

#

318 value

<

0.05*#358 value

error

0.05*#358 value

≦

#

318 value

<

0.1 *#358 value

warning

0.1 *#358 value

≦

#

318 value

≦

0.7 *#358 value

normal

0.7 *#358 value

<

#

318 value

≦

0.75*#358 value

warning

0.75*#358 value

<

#

318 value

error

[Software zero signal type]

#

318 value

<

0.05*#358 value

error

0.05*#358 value

≦

#

318 value

<

0.1 *#358 value

warning

0.1 *#358 value

≦

#

318 value

≦

0.4 *#358 value

normal

0.4 *#358 value

<

#

318 value

≦

0.45*#358 value

warning

0.45*#358 value

<

#

318 value

error