Panasonic WV-CL924A User Manual

Page 31

Advertising
background image

-32-

2. After confirming the cursor is on LL, press

. The

vertical phase adjustment menu appears on the
monitor.

3. Supply the video output signal of the camera to be

adjusted and the reference camera video output
signal to a dual-trace oscilloscope.

4. Set the oscilloscope to the vertical rate and expand

the vertical sync portion on the oscilloscope.

5. Move the cursor to COARSE. The cursor starts

blinking.

6. Press

or

to match the vertical phase for

both video output signals as closely as possible.
(COARSE adjustment can be incremented in 16
steps by 22.5 degrees by pressing

or

.)

Note:

After the sixteenth step, the adjustment

returns to the first step.

7. Move the cursor to FINE.
8. Press

or

to match the vertical phase for

both video output signals as closely as possible.
(FINE adjustment can be made up to 22.5 degrees
by pressing

or

.)

Notes:

• When the “I” cursor reaches the “+” end, it

jumps back to “

”. At the same time, COARSE

is incremented by one step to enable a contin-
uous adjustment. The reverse takes place
when the “I” cursor reaches the “

” end.

• When

or

is kept pressed for a second

or more, the “I” cursor moves faster.

1 (1 - - - 16): 0 degrees
2 (1 - - - 16): 22.5 degrees

16 (1 - - - 16): 337.5 degrees

** SYNC **

V PHASE

COARSE 1(1--16)

FINE I........
- +

RET END

Advertising