The Text Commands
13
The Text Commands
The following commands are used to present text blocks in a page, a page
segment, or an overlay.
Load Equivalence (LE)
Byte
D61D
Flag
CID
Data
Count
This command allows the printer to use a single suppression ID for more than
one suppression pair.
Write Text (WT)
Byte
D62D
Flag
CID
Presentation
Count
Text Object;
Content
Architecture
control codes
and character
data
Use this command to send character data and controls to the printer. The
data and controls can begin in one Write Text command chain and end in
another Write Text command chain.
Controls are listed on the following pages. The first control is preceded by the
escape sequence 2B D3. Subsequent controls will follow as long as the
preceding code is a chained code.