PROBLEM

CAUSE

CORRECTION

Motor will not
run.

Fuse blown, circuit breaker
tripped.

1. Check fuse box for blown

fuse and replace as
necessary. Reset circuit
breaker. Do not use a
fuse or circuit breaker
with higher rating than
that specified for your
particular branch circuit.

2. Check for proper fuse. You

should use a time delay
fuse.

3. Check for low voltage

conditions and/or proper
extension cord.

4. Disconnect

the

other

electrical appliances from
circuit or operate the
compressor on its own
branch circuit.

Motor overload protection
switch has tripped

Let motor cool off and
overload switch will
automatically reset.

Tank pressure exceeds
pressure switch "cut-in"
pressure.

Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.

Loose electrical
connections.

Check wiring connection
inside pressure switch and
terminal box area.

Have checked by a Trained
Service Technician.

Check valve stuck open.

Remove and clean, or replace.

Possible defective motor
or starting capacitor.

Have checked by a Trained
Service Technician. Do not
operate the compressor in
the paint spray area. See
flammable vapor warning.

Paint spray on internal
motor parts.

Bleed the line by pushing the
lever on the pressure switch to
the "OFF" position; if the valve
does not open, replace switch.

Pressure release valve on
pressure switch has not
unloaded head pressure.