Porter-Cable C2004 User Manual

Page 16

Advertising
background image

16 - ENG

PROBLEM

CAUSE

CORRECTION

Air leak from

safety valve.

Possible defect in

safety valve.

Operate safety valve

manually by pulling on

ring. If valve still leaks,

it should be replaced.

Knocking Noise.

Possible defect in

safety valve.

Operate safety valve

manually by pulling on

ring. If valve still leaks,

it should be replaced.

Pressure reading on

the regulated pressure

gauge drops when an

accessory is used.

It is normal for "some"

pressure drop to occur.

If there is an excessive

amount of pressure drop

when the accessory

is used, adjust the

regulator following

the instructions in

the

Description of

Operation paragraph in

the Operation Section.

NOTE: Adjust the

regulated pressure

under flow conditions

(while accessory

is being used).

Compressor is not

supplying enough air to

operate accessories.

Prolonged excessive

use of air.

Decrease amount

of air usage.

Compressor is not

large enough for

air requirement.

Check the accessory

air requirement. If

it is higher than the

SCFM or pressure

supplied by your air

compressor, you need

a larger compressor.

Hole in hose.

Check and replace

if required.

Check valve restricted.

Contact a Trained

Service Technician

Air leaks.

Tighten fittings.

Regulator knob has

continuous air leak.

Damaged regulator.

Replace.

Regulator will not

shut off air outlet.

Damaged regulator.

Replace.

Advertising
This manual is related to the following products: