With Time & Date Clock, GLP-Compliance and WinCT as
standard. Plus all the other features you need.

•

GLP/GMP/ISO Compliance
Allows GLP or LIMS balance management by out-
putting and the balance ID Number and data used to
calibrate the balance. The data can be output to
A&D’s AD-8121 or DP-1012 printer or a computer,
indicating date, time, balance ID Number, serial
number and calibration data.

•

Standard Windows Communication Tools
Software WinCT
WinCT provides easy transmission of weighing data
from a GX or GF balance to a computer using the
RS-232 C interface. Quickly exports data into
Windows applications in a manageable format limited
only by the computers capabilities.

•

RS-232C Interface
Incorporates bi-directional communication with a PC,
printer or other peripheral device.

•

Density Calculation Mode
Automatically calculates and displays the density
measurement results;
- Input the temperature of water,
- Input the liquid’s density directly

(Range: 0.000 – 1.9999g/cm

3

)

•

Data Memory – GX
Format the Data Memory Function for:
- 200 sets of weighing data
- 100 sets of weighing data with Time & Date
- 50 sets of GLP Data – Time & Date, Calibration

Data, ID Number and Serial number

- 20 sets of Unit Weight for Counting Mode

•

Data Memory – GF
Format the Data Memory Function for:
- 40 sets of weighing data
- 20 sets of Unit Weight for Counting Mode

•

Time & Date – GX
Standard Time & Date Function complies with GLP
and Interval Weighing in the Data Memory Function.

•

Commands
A PC can control the balance by sending commands
to the balance. Commands to query weighing data;
to control the balance; to control the memory func-
tion, to control comparator function.

•

Internal Calibration - GX
All GX balances provide an internal calibration and
perform self calibration using the internal mass when
the balance detects ambient temperature changes.
The One-Touch Calibration lets you adjust the
calibration on demand at the press of a single button.

•

Standard Underhook
Ideal for density determination and weighing magnetic
and highly static objects.

•

Interval Time Setting
Weighing intervals of 2, 5, 10 minutes in the Data
Memory Function.

•

Auto Self Checking
Automatically checks itself when setting the
Automatic Adjustable Environment.

•

Auto Re-Zero
Re-zeroes automatically after data output.

•

Large Square Weighing Pan
Standard large square weighing pan on all models.
GX200/400/600: 128 x 128 mm
GF200/300: 128 x 128 mm
GX2000, 4000, 6100, 6000, 8000: 165 x 165 mm
GF1200, 2000, 3000, 6000: 165 x 165 mm

•

Multiple Weighing Units and Programmable Unit
Uses programmable or standard units of measure
(g, ct, newtons, plus many more including a free unit
which can be set by the operator)

•

Front Air Bubble Leveling
Easy check the balance’s level from the front.

•

Quick Reference Card
A fast, convenient operating guide installed at the
bottom of the balance.