RS232 Communications Protocol & Command Set

(continued)

Condition

CL Outlet Bank switches ON

CL Outlet Bank switches OFF

NCL Outlet Bank switches ON

NCL Outlet Bank switches OFF

Response from UPS

CL_OUTLETS_ON<CR>

CL_OUTLETS_OFF<CR>

NCL_OUTLETS_ON<CR>

NCL_OUTLETS _OFF<CR>

Responses and Warning Messages
A warning message is to be transmitted whenever the status of the fol-
lowing systems changes:

Outlet Bank Status Messages
Whenever an outlet bank switches state (ON or OFF) the UPS sends a
message to the controller:

Condition

UPS is not in AVR or BATTERY
mode

UPS is in AVR boosting 13%

UPS is in AVR boosting 26%

UPS is in AVR bucking 15%

UPS is in BATTERY mode

Battery charge falls below critical
load threshold

Input voltage exceeds high volt-
age failure t’hold

Input voltage falls below low
voltage failure t’hold

Battery charge falls below critical
load threshold

Response from UPS

NORMAL<CR>

AVRBOOST1<CR>

AVRBOOST2<CR>

AVRBUCK1<CR>

BATTERY<CR>

LOWBATT<CR>

OVERVOLTAGE<CR>

UNDERVOLTAGE<CR>

LOWBATT<CR>

Power Status Messages
Whenever the power changes state the UPS sends a message to the
controller:

Invalid Command or Query

If the UPS receives a command or query ASCII string that it does not
understand, an error message is transmitted.

Condition:

Command or query not recognized or
properly formatted

Response from UPS:

INVALIDCMD<CR>