MODELLING LAMP (4)

The modelling light consists of a lamp that is fed directly

from the mains. It is therefore important to check that

the lamp has a rated voltage that matches that of the

mains. The lamp supplied as standard is a 150 - 250W

halogen lamp with an E27 base (ComPact Special 300

and ComPact Special 600) or a 500W halogen lamp with

an E11 Minican base with the ComPact 1200.

The ComPact 300 and ComPact 600 can also be

supplied with a normal 100W lamp with an E27 base.

To improve the correspondence between the modelling

light and flash, the flash tube and modelling lamp is

enclosed in a frosted glass cover (standard in all models

with halogen modelling lamps).

BEFORE YOU CHANGE THE MODELLING LAMP OR

FLASH TUBE, DISCHARGE THE POWER IN THE UNIT

BY PRESSING THE TEST BUTTON AT THE SAME TIME

AS SWITCHING OFF THE MAIN SWITCH.

READY LAMP/TEST BUTTON (5)

The ready lamp/test button has two functions. First, it

lights up when the unit is fully charged. Second, it can

be used to manually sync (trigger) the unit (open flash).

When a lower energy setting is chosen , trigger a flash

so that the unit can recycle for the new energy setting.

PHOTOCELL

The units has a built-in photocell. The photocell in

the unit serves as a slave sync when another flash is

triggered. The photocell is automatically disabled

when a sync cable is plugged in.

English –