54

Pelco Manual C681M-D (2/02)

16. Turn the SHUTTLE ring to the left to return to the Timer Program menu. Repeat steps

3-15 to define other patterns.

17. When you finish defining patterns, do one of the following:

•

Proceed to the next section (

Motion Detection During a Timer Recording ) to set

up motion detection to operate during a timer recording (DX3016 models only).

•

Turn the SHUTTLE ring to the left twice to return to the Menu Setting menu to go
to another menu.

•

Press the SET UP button to exit the programming mode.

When timer settings overlap, the unit will give priority to the higher-numbered program.

Example 1

•

Program 1 is set for 14:00 to 17:00 with a recording interval of 3F.

•

Program 2 is set for 15:00 to 16:00 with recording interval of 5F.

Under this condition, the unit will give priority to Program 2 for the duration of the over-
lapping period, from 15:00 to 16:00. The unit will operate as shown in the illustration
below.

Example 2

•

Program 1 is set for 14:00 to 17:00 with a recording interval of 3F.

•

Program 2 is set for 15:00 to 16:00 with the SKIP setting.

Again, the unit will give priority to Program 2 for the duration of the overlapping period.
As shown in the illustration below, the unit will activate the Skip setting from 15:00 to
16:00.

Example 1)

In Program #1, recording is set for every
3F, from 14:00 to 17:00.

14:00

15:00

16:00

17:00

14:00

15:00

16:00

17:00

5F

In Program #2, recording is set for
every 5F, from 15:00 to 16:00.

Actual recording will occur as follows.

3F

3F

Setting for the prioritized Program #2.


In this situation, the unit gives priority to the higher-numbered Program #2.

3F

5F

Example 2)

In Program #1, recording is set for
every 3F, from 14:00 to 17:00.

14:00

15:00

16:00

17:00

14:00

15:00

16:00

17:00

SKIP

In Program #2, the SKIP setting is
entered for 15:00 to 16:00.

3F

3F

3F

NO

RECORDING!

Actual recording

Setting for the prioritized Program #2.


In this situation, the unit gives priority to the higher-numbered Program #2.

Advertising