Pioneer Sound.Vision.Soul PRV-LX1 User Manual

Page 12

Advertising
background image

PRV-LX1 RS-422A Protocol

E2 51 21 Chapter Search (PRV-LX1 original command)

The command searches to a recorded chapter number

Values are 1-99 (0x01 – 0x99)

DATA – 2

10

Chapters

1

Chapter

MSD LSD

Chapter number is given by DATA-2. Available chapter numbers are from 1 to 99.

E1 51 22 Chapter Mark (PRV-LX1 original command)

This command inserts a chapter mark in the Title being recorded.

E1 51 81 Title Number Sense (PRV-LX1 original command)

The command returns the total number of titles in the selected project when playback is stopped

and returns the recording title number when recording. When a title is playing or in TimeShift

PLAY, the unit returns the playing title number. “E3 51 91 n n Title Number Data”, where nn is the

title number.

E3 51 91 Title Number Data (PRV-LX1 original command)

This command corresponds with the “E1:51:81 Title Number Sense” command. The unit returns

the total number of titles in the selected project when playback is stopped and returns to the

recording title number when recording. When a title is playing or in TimeShift PLAY, the unit

returns the playing title number. Data format is the same as the “E3:51:11 Title Search”

command.

E1 51 82 Chapter Number Sense (PRV-LX1 original command)

This command returns current chapter number, “E3 51 92 nn Chapter Number Data”, where nn is

the chapter number. When recording, the unit returns the recording chapter number executed by

the ”E3:51:92 Chapter Number Data” command.

Returns the playing chapter number during playback or in TimeShift PLAY.

E3 51 92 Chapter Number Data (PRV-LX1 original command)

This command corresponds with the “E1:51:82 Chapter Number Sense” command. The unit

returns the recording chapter number when recording. When a chapter is playing or in TimeShift

PLAY, the unit returns the playing chapter number. Data format is the same as the “E2:51:21

Chapter Search” command.

E3 51 71 Title Delete (PRV-LX1 original command)

The command deletes the recorded title number.

Values are 1-255 (0x01 0x00 – 0x55 0x02)

When a stopped unit receives this command, the title specified by Data–2 and Data–3 is deleted.

With the ”E1:51:8F Mode Sense” command, it is possible to know if the deletion is complete.

Issuing the ”E1:51:81 Title Number Sense” command before and after the deletion, confirms that

the number of titles in the selected project has been reduced. If the number of titles has not been

reduced then the title deletion has failed so error handling should be executed. Data format is the

same as the “E3:51:11 Title Search” command.

Page 11 of 18