4.2 CONFIGURING DIP SWITCH S1

DIP switch S1 is where you configure the CopperLINK line. The following
tables describe the configuration for the 2151.

5.0 OPERATION

Once the Model 2151s are properly installed, they should operate trans-
parently. No user settings required. This section describes reading the
LED status monitors.

5.1 POWER UP

Before applying power to the Model 2151, please review section 3.3,
“Connecting Power” on page 12
to verify that the unit is connected to the
appropriate power source.

Table 1:

2151 Firmware Configuration

Position

S1-1

S1-2

S1-3

S1-4

Master/

Slave

Rate

ON

Slave

(CPE)

4/1, 9/1, 16/2, 6/6, 10/10, 15/15

Rate Control (See table below).

OFF

Master

(CO)

S1-2

S1-3

S1-4

Rate

(DS/US)

*

*. DS = Downstream, US = Upstream

OFF

OFF

OFF

4/1

ON

OFF

OFF

9/1

OFF

ON

OFF

16/2

ON

ON

OFF

6/6

OFF

OFF

ON

10/10

ON

ON

ON

15/15