Paradyne COMSPHERE 3615 User Manual

Page 96

Advertising
background image

Status Indicators and Control Panel Messages

C-5

3615-A2-GB20-20

December 1996

Table C-3

(2 of 3)

Device Health and Status Messages

Condition

Message

Dial Tone:Fail

Dial tone test was enabled and test failed.

DDS F:

alarm

Digital facility alarm;

alarm is one of the following network alarms:

BiplrViol

—

Excessive Bipolar Violations

Fac Alarm

—

Facility Alarm

OutofServc

—

Out-of-Service condition

No Signal

—

No signal has been received

DSU:Device Fail

Internal failure in the DSU is detected. (Go to the Test branch for Device Test.)

DSU:Disable

DSU transmitter is disabled. (Go to the Control branch to enable the DSU.)

DSUTst:

test,init

The DSU is running a test, initiated from

init.

test is one of the following tests:

BERT

—

Bit Error Rate Test

BiL

—

Bilateral Loopback

Dev

—

Device Test

DL

—

Digital Loopback

DT

—

Digital Test

DTE

—

DTE Loopback

Lamp

—

Lamp Test

NetL

—

Network Loopback

TM

—

Test Mode

init is one of the following initiators:

DCP

—

Diagnostic Control Panel

DTE

—

Data Terminal Equipment

NMS

—

Network Management System

Ntwk

—

Network

Remt

—

Remote DSU

External Alarm A

The DSU detects a positive voltage on Pin 23. This alarm condition is defined by the
Ext Leads configuration option.

External Alarm B

The DSU detects a positive voltage on Pin 19. This alarm condition is defined by the
Ext Leads configuration option.

Invalid Address

A DSU was powered up with an invalid address. Invalid addresses are:

0

—

This is reserved for the SDU

192

—

This is reserved for the broadcast address

191

—

Invalid for a DSU with a DBM because of the reserved 192
broadcast address

255

—

Invalid for a DSU with a DBM