12.0

Changing Components

39

12.22

Diverter Valve Assembly (Cont)

CH Pressure Differential Valve Diaphragm (Fig. 70)

1. Isolate the boiler from the central heating flow and

return pipes and drain the boiler primary circuit.

2. Prise off the spring clip retaining the microswitch. Pull

the switch away.

3. Undo the screws securing the differential valve cover.

4. Carefully draw off the cover and remove the

diaphragm.

5. Fit the new diaphragm and reassemble in reverse

order.

Diverter Valve Operating Head (Fig. 70)

1. Pull the 3-pin plug off the operating head and prise off

the spring clip retaining the head to the valve body.

2. Lift the operating head away from the valve body.

3. Fit the new head and reassemble in reverse order.

12.23

Flow Regulator (Figs. 71 & 72)

1. Undo the filter cartridge from the inlet/return

manifold.

2. Unscrew the venturi and remove the flow regulator.

3. Check the cleanliness of the filter gauze, rinsing

thoroughly in clean water as necessary. Fit the new flow

regulator and reassemble in reverse order.

Fig. 70

Cartridge

Body

Filter Gauze

Flow

Regulator

Venturi

Inlet/Return Manifold

Fig. 71

Fig. 72

Diverter Valve

Microswitch

Diverter Valve

Operating Head

3-pin Plug

Pushrod

Diaphragm

Spring

Diaphragm

Spring Clip

CH Pressure

Differential Valve

Cover

Spring Clip