PROBLEM

CAUSE

CORRECTION

Pressure switch does
not shut off motor when
compressor reaches "cut-
out" pressure.

Pressure switch "cut-out"
too high.

Move On/Auto/Off lever
to the "OFF" position, if
the outfit does not shut off
contact a Trained Service
Technician.
Contact a Trained Service
Technician.

Excessive
tank pressure
- safety valve
pops off.

Tube fittings are not tight
enough.

Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution. DO NOT
OVERTIGHTEN.

Air leaks at
fittings.

Air leaks at
pressure switch
release valve.
(if equipped)

Defective pressure switch
release valve.

Contact a Trained Service
Technician.

Air leaks in air
tank or at air
tank welds.

Defective air tank.

Air tank must be replaced.

Do not

repair

the leak.

Do not drill into,

weld or otherwise modify

air tank or it will weaken.

The tank can rupture or

explode.

Air leaks
between head
and valve plate.

Leaking seal.

Contact a Trained Service
Technician.

Air leaks at or

inside check

valve

Check valve seat damaged.

A defective check valve

results in a constant air leak

at the pressure release valve

when there is pressure in the

tank and the compressor

is shut off. Replace check

valve. Refer the "To Replace

or Clean Check Valve" in the

"Service and Adjustment"

section.