line and oil at a ratio of 40:1. A 40:1 ratio is ob-

tained by mixing 3.2 ounces (95 ml) of oil with 1

gallon (4 liters) of unleaded gasoline. DO NOT

USE automotive oil or marine oil. These oils

will cause engine damage. When mixing fuel,

follow instructions printed on container. Once

oil is added to gasoline, shake container mo-

mentarily to assure that the fuel is thoroughly

mixed. Always read and follow the safety

rules relating to fuel before fueling your unit.

IMPORTANT

Experience indicates that alcohol blended

fuels (called gasohol or using ethanol or

methanol) can attract moisture which leads to

separation and formation of acids during stor-

age. Acidic gas can damage the fuel system

of an engine while in storage. To avoid engine

problems, empty the fuel system before stor-

age for 30 days or longer. Drain the gas tank,

start the engine and let it run until the fuel lines

and carburetor are empty. Use fresh fuel next

season. Never use engine or carburetor

cleaner products in the fuel tank or permanent

damage may occur.

See the STORAGE section for additional in-

formation.

HOW TO STOP YOUR UNIT

S

To stop the engine, move the ON/OFF

switch to the OFF position.

S

If engine does not stop, move choke lever

to FULL CHOKE position.

Throttle Trigger

ON/OFF

Switch

HOW TO START YOUR UNIT

WARNING:

Avoid any contact with

the muffler. A hot muffler can cause serious

burns.

HELPFUL TIP

If your engine still does not

start after following these

instructions, please call

1--800--554--6723.

STARTING A COLD ENGINE (or a

warm engine after running out of

fuel)

Starting Position

Muffler

Choke

Lever

Starter Handle

Primer Bulb

1. Set unit on a flat surface.

2. Move ON/OFF switch to the ON position.

3. Slowly press the primer bulb 6 times.

4. Move choke lever to FULL CHOKE by

aligning lever with position shown on de-

cal (see illustration below).

Choke

position

decal

5. Squeeze the throttle trigger fully and hold

through all remaining steps.

6. Pull starter rope handle sharply until en-

gine sounds as if it is trying to start, but do

not pull rope more than 6 times.

7. As soon as engine sounds as if it is trying

to start, move choke lever to HALF

CHOKE by aligning lever with position

shown on decal (see illustration below).

Choke

position

decal

8. Pull starter rope sharply until engine runs,

but no more than 6 pulls. If the engine

doesn’t start after 6 pulls (at the HALF

CHOKE position), move the choke lever to

the FULL CHOKE position and press the

primer bulb 6 times. Squeeze and hold the

throttle trigger and pull the starter rope 2

more times. Move the choke lever to the

HALF CHOKE position and pull the starter

rope until the engine runs, but no more than

6 pulls. If the engine doesn’t start, repeat

procedure 2 additional times.

NOTE:

If engine still doesn’t start, it is

probably flooded. Proceed to STARTING A

FLOODED ENGINE.

9. Once the engine starts, allow it to run 10 se-

conds, then move the choke lever to OFF

CHOKE by aligning lever with position

shown on decal (see illustration below). Al-

low the unit to run for 30 more seconds at

OFF CHOKE before releasing the throttle

trigger.