Maintenance storage, Storage, Storage time prior to storing – Poulan Pro PP4300 User Manual

Page 20: Maintenance schedule

Advertising
background image

STORAGE

When preparing the generator for storage, follow the guidelines below.

STORAGE TIME

PRIOR TO STORING

Less than 1 month

No special preparation is required.

■

1 to 2 months

Fill with fresh gasoline and add a gasoline conditioner*.

■

2 months to 1 year

Fill with fresh gasoline and add a gasoline conditioner*.

Drain fuel from carburetor.

Clean fuel sediment cup.

■
■
■

1 year or more

Drain fuel tank.

Drain fuel from the carburetor.

Clean fuel sediment cup.

Remove spark plug.

Put a tablespoon of engine oil into the spark plug cylinder. Turn the engine slowly with

■
■
■
■
■

the pull rope to distribute the oil.

Reinstall spark plug.

Change engine oil.

■
■

After removal from storage:

Fill with fresh gasoline.

■

*Use gasoline conditioners formulated to extend storage life. For recommendations, contact your nearest authorized

service center.

MAINTENANCE

STORAGE

20

MAINTENANCE SCHEDULE

S E R V IC E IT E M S

E A C H

U S E

F IR S T

M O N T H O R

2 0 H O U R S

E V E R Y

3

M O N T H S O R

5 0 H O U R S

E V E R Y

6

M O N T H S O R

1 0 0 H O U R S

E V E R Y

Y E A R O R

3 0 0 H O U R S

G e n e ra l In s p e c tio n

X

1

C h e c k O il L e v e l

X

C h a n g e E n g in e O il

X

X

C le a n A ir C le a n e r

X

2

C le a n C ylin d e r C o o lin g F in s

X

2

C le a n S p a rk P lu g

X

C le a n th e S p a rk A rre s to r

X

C le a n F u e l S e d im e n t C u p

X

3

C le a n F u e l T a n k

X

3

A d ju s t V a lv e C le a ra n c e

X

3

C h e c k fu e l lin e

E v e r y 2 ye a rs (R e p la c e if n e c e s s a ry)

3

Advertising