Major operating controls and their functions – Panasonic WV-CP240 User Manual

Page 2

Advertising
background image

Caution:

To prevent fire or electric shock hazard, use
a UL listed cable (VW-1, style 1007) for the
DC 12 V or AC 24 V Input Terminal.

Cautions:

• Connect to 12 V DC (10.5 V-16 V) or 24 V

AC (19.5 V-28 V) class 2 power supply only.
Make sure to connect the grounding lead to
the GND terminal when the power is sup-
plied from a 24 V AC power source.

• To prevent fire or electric shock hazard, use

a UL listed cable (VW-1, style 1007) for the
DC 12 V or AC 24 V Input Terminal.

GND

AC 24V IN

1

2

VIDEO OUT

VIDEO OUT

VIDEO OUT

<WV-CP240>

<WV-CP244>

<WV-CP242>

DC 12V IN

WV–

CP244

LL

INT

ELC

ALC

SOFT

SHARP

OFF

BLC ON

DC

VIDEO

ELC

ALC

SOFT

SHARP

OFF

BLC ON

DC

VIDEO

LL

INT

ELC

ALC

SOFT

SHARP

OFF

BLC ON

DC

VIDEO

LL

INT

ELC

ALC

SOFT

SHARP

OFF

BLC ON

DC

VIDEO

ELC

ALC

SOFT

SHARP

OFF

BLC ON

DC

VIDEO

LOCK

Fixing Screws

Camera Mounting
Screw Holes

Mount Adapter

cs

c

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

q

Auto Iris Lens Connector

Supplies power and control signals to an auto
iris lens (not supplied).

w

Flange-back Adjusting Ring

This ring adjusts the back-focal distance or
picture focus. Rotate this ring clockwise for a
C-mount lens or counterclockwise for a CS-
mount lens.

e

Lens (option)

r

Mount Adapter

The camera mounting screw hole is for
mounting the camera onto a mounting brack-
et. The camera is originally designed to be
mounted from the bottom, however, a top-
mounting type is also available. To mount
from the top, remove the mount adapter from
the bottom of the camera by removing two
fixing screws. Attach the mount adapter to
the top as shown in the diagram, then mount
the camera on the mounting bracket. Make
sure that two original screws are used when
mounting the mount adapter; longer type
screws may damage inner components, too
shorter type screws may cause the camera
drop.

t

Focus Fixing Screw

y

Power Cord (only for WV-CP240)

Connect this power cord to an electrical out-
let of 120 V AC 60 Hz.

u

DC 12 V Input Terminal
[DC 12V IN (only for WV-CP242)]

This terminal is for connecting the 12 V DC
power supply cord.

i

AC 24 V Input Terminal
[AC 24V IN (only for WV-CP244)]

This terminal is for connecting the 24 V AC
60Hz power supply cord.

o

Synchronization Mode Selector
[INT, LL (only for WV-CP240 and WV-
CP244)]

Selects the camera synchronization mode as
either internal sync mode (INT) or line-lock
mode (LL).

INT:

Sets to internal 2:1 interlace.

LL:

Sets to Line-lock mode.

!0

Back Light Compensation Mode Selector
(BLC ON, OFF)

Lets you select the mode according to the
position of the object and light conditions on
the screen.

ON:

Select this mode when a strong light

such as a spotlight is in the background.

OFF:

Normal picture.

!1

Detail/Aperture Level Selector (SHARP,
SOFT)

The detail/aperture level can be selected with
this selector. Set it to the desired position
while observing the picture on the monitor.

SHARP:

Normal position.

SOFT:

Select this position when a Quad

System is connected to this camera.

!2

Automatic Light Control/Electronic Light
Control Selector (ALC, ELC)

Lets you select the mode according to the
lens type used.

ALC:

Select this mode when an auto iris lens

(ALC lens) is used with this camera.

ELC:

Select this mode when a fixed iris lens

or manual iris lens is used with this cam-
era.

!3

Lens Drive Signal Selector (VIDEO, DC)

Lets you select the mode according to the
type of auto iris lens drive signal to be sup-
plied to the lens from the auto iris lens con-
nector.

VIDEO:

Select this mode if you are using a

auto iris lens that requires a video drive
signal.

DC:

Select this mode if you are using a auto
iris lens that requires a DC drive signal.

!4

Video Output Connector (VIDEO OUT)

This connector is for connecting with the
VIDEO IN connector of the video monitor.
Whenever the multiplexed vertical drive (VD2)
signal is supplied to this connector, the cam-
era synchronization mode is automatically set
to Vertical Drive.

Whether the camera is in use or not, never
aim it at the sun or other extremely bright
objects. Otherwise, blooming or smear may
be caused.

7. Do not operate the camera beyond the

specified temperature, humidity or power
source ratings.

Use the camera under conditions where tem-
perature is between –10°C - +50°C (14°F -
122°F), and humidity is below 90 %. The
input power source is 120 V AC 60 Hz for
WV-CP240, 12 V DC for WV-CP242, and 24 V
AC 60 Hz for WV-CP244.

Advertising