Specifications

• Power plugs are not supplied with the unit.

• Electrical work must be installed by a licensed electricians. Be sure to use the correct rating of the

power plug and mains circuit for the model to be installed.

• Please read the Installation Instructions carefully before installing the unit, and read the Operating

Instructions before using.

Power

Supply

27°C DB/19°C WB

20°C DB

35°C DB

7°C DB/6°C WB

Cooling

Inside air temperature

Outside air temperature

Heating

Rating Conditions

Single Split

*

1

Sound Pressure Level is measured according to JIS C 9612.

*

2

Additional Gas might be required for some models.

Power

Supply

W/W

Maximum

Pipe

Length

*

2

Model No.

CS-W7DKR

(CU-W7DKR)

CS-W9DKR

(CU-W9DKR)

CS-W12EKR

(CU-W12EKR)

CS-W18DKR

(CU-W18DKR)

CS-W24EKR

(CU-W24EKR)

7,840

9,380

12,300

18,100

24,000

2.30

2.75

3.60

5.30

7.03

L/h

1.5

1.6

2.1

2.9

4.0

Outdoor (Hi)

kg

9

(26)

9

(29)

8

(35)

11.0

(56.0)

11.0

(63.0)

mm

280 x 799 x 183

(510 x 650 x 230)

280 x 799 x 183

(510 x 650 x 230)

280 x 799 x 183

(540 x 780 x 289)

275 x 998 x 230

(750 x 875 x 345)

275 x 998 x 230

(750 x 875 x 345)

8,350

10,400

13,300

19,600

26,600

2.45

3.05

3.90

5.75

7.80

Cooling Capacity

Heating Capacity

Air Flow

Dehumid Running

Current

Power

Input

EER

COP

Sound Pressure

Level

*

1

dB (A)

Sound Power

Level dB

Net Weight

Dimensions

Height x Width x Depth

L/s

143

162

A

3.2

3.0

3.8

3.8

5.0

4.9

7.8

7.8

11.1

11.7

kW

0.72

0.685

0.875

0.865

1.1

1.09

1.81

1.80

2.37

2.46

3.19

3.58

3.14

3.53

3.27

3.58

2.93

3.19

2.97

3.17

Indoor

(Hi/Lo/S-Lo)

34/26/23

36/26/23

36/26/23

39/26/23

41/29/26

42/29/26

43/38/35

42/38/35

47/41/38

46/41/38

Outdoor (Hi)

47

49

49

50

50

50

50

51

53

54

132

152

63

64

62

64

64

65

65

66

66

67

Star

Rating

(50Hz/240V)

m

10

10

15

25

25

Indoor

Indoor

Indoor

Indoor

Indoor

178

182

255

267

290

303

5.0

6.0

4.5

5.5

4.5

4.5

4.0

3.5

3.5

3.0

Btu/h

kW

Single Inverter Split

Btu/h

kW

L/h

Outdoor(Hi)

A

kW

W/W

kg

mm

Indoor (Hi/Lo/S-Lo) Outdoor (Hi/S-Lo)

Cooling Capacity

Heating Capacity

Air Flow Dehumid Running

Current

Power

Input

EER

COP

Sound Pressure

Level

*

1

dB (A)

Sound Power

Level dB

Net Weight

Maximum

Pipe

Length

*

2

m

Dimensions

Height x Width x Depth

Model No.

(50Hz/240V)

L/s

Star

Rating

6.30

(0.90~7.10)

7.20

(0.90~8.50)

21,500

(3,070~24,200)

24,600

(3,070~29,000)

10

(51)

275 x 998 x 230

(750 x 875 x 345)

3.5

20

3.06

3.60

45 / 37 / 34

45 / 37 / 34

48 / 43

49 / 44

9.0

8.8

2.06

(0.215~2.40)

2.00

(0.245~2.70)

61

62

270

288

4.0

4.5

Outdoor

8.10

(0.90~8.60)

9.60

(0.90~11.00)

27,600

(3,070~29,300)

32,700

(3,070~37,500)

11

(63)

275 x 998 x 230

(795 x 900 x 320)

4.8

30

2.98

2.95

49 / 38 / 35

48 / 38 / 35

53 / 48

53 / 48

67

67

12.0

14.4

2.72

(0.35~2.95)

3.25

(0.36~3.79)

295

312

3.5

3.0

Outdoor

CS-E9GKR

(CU-E9GKR)

2.60

(0.80~3.00)

3.60

(0.80~5.00)

8,870

(2,730~10,200)

12,300

(2,730~17,100)

9

(34)

280 x 799 x 183

(540 x 780 x 289)

1.6

15

4.33

4.26

39 / 26 / 21

40 / 27 / 24

46 / —

47 / —

2.8

3.8

0.60

(0.175~0.78)

0.845

(0.165~1.36)

59

60

173

183

6.0

6.0

Outdoor

CS-E15GKR

(CU-E15GKR)

4.40

(0.90~5.00)

5.50

(0.90~7.10)

15,000

(3,070~17,100)

18,800

(3,070~24,200)

9

(47)

280 x 799 x 183

(750 x 875 x 345)

2.4

15

3.21

3.50

43 / 32 / 25

43 / 35 / 32

46 / 41

46 / 41

6.2

7.0

1.37

(0.215~1.60)

1.57

(0.245~2.25)

59

59

183

197

4.5

4.5

Outdoor

CS-E18GKR

(CU-E18GKR)

5.30

(0.90~6.00)

6.60

(0.90~8.00)

18,100

(3,070~20,500)

22,500

(3,070~27,300)

10

(49)

275 x 998 x 230

(750 x 875 x 345)

2.9

20

3.21

3.69

44 / 37 / 34

44 / 37 / 34

47 / 42

47 / 42

7.3

7.9

1.65

(0.215~2.05)

1.79

(0.245~2.65)

60

60

253

278

5.0

5.0

Outdoor

CS-E12GKR

(CU-E12GKR)

3.50

(0.80~4.00)

4.90

(0.80~6.70)

11,900

(2,730~13,600)

16,700

(2,730~22,800)

9

(35)

280 x 799 x 183

(540 x 780 x 289)

2.0

15

3.63

3.89

42 / 29 / 21

42 / 33 / 30

48 / —

50 / —

61

63

4.3

5.6

0.965

(0.185~1.20)

1.26

(0.175~1.89)

187

195

6.0

5.5

Outdoor

Cooling

Heating

EER: Cooling Efficiency

COP: Heating Efficiency

( ): Outdoor Unit

CS-E21GKR

(CU-E21GKR)

7.40

(0.90~8.10)

8.60

(0.90~9.90)

25,200

(3,070~27,600)

29,300

(3,070~33,800)

11

(63)

275 x 998 x 230

(795 x 900 x 320)

4.3

30

3.02

3.43

47 / 38 / 35

47 / 38 / 35

52 / 47

52 / 47

11.0

11.1

2.45

(0.35~2.70)

2.51

(0.36~3.20)

66

66

282

305

4.0

4.0

Outdoor

CS-E24GKR

(CU-E24GKR)

CS-E28GKR

(CU-E28GKR)

Air Conditioners

2007 / 2008

Energy

Materials

Factories

Our energy-conservation technologies help
to minimise energy consumption.

None of the products we ship contain any
specified chemical substances* regardless
of market.

* Lead, cadmium, hexavalent chromium, mercury, specified
bromine frame retardants (PBB, PBDE)

Our manufacturing sites around the world
have acquired ISO 14001 certification.

The Matsushita Group actively develops environmentally-conscious products.

Panasonic Australia Pty Limited.

ACN 001 592 187 ABN 83 001 592 187

HO/NSW:

Austlink Corporate Park, 1 Garigal Rd,

Belrose NSW 2085

Ph: (02) 9986 7400 Fax: (02) 9986 7600

Visit our website at: www.panasonic.com.au or email our Customer Care Centre on [email protected]

Specifications are subject to change without notice. While every effort has been made to represent product colours accurately, slight variation may occur due to the printing process. TV pictures are simulated in an effort to explain product features.

Panasonic Australia Pty Limited.

ACN 001 592 187 ABN 83 001 592 187

HO/NSW:

Austlink Corporate Park, 1 Garigal Rd,

Belrose NSW 2085

Ph: (02) 9986 7400 Fax: (02) 9986 7600

Visit our website at: www.panasonic.com.au or email our Customer Care Centre on [email protected]

Specifications are subject to change without notice. While every effort has been made to represent product colours accurately, slight variation may occur due to the printing process. TV pictures are simulated in an effort to explain product features.

www.panasonic.com.au

VIC/TAS

1 Keith Campbell Court, Scoresby VIC 3179

Ph: (03) 9213 8888 Fax: (03) 9213 8810

QLD

494 Nudgee Road, Hendra QLD 4011

Ph: (07) 3308 6455 Fax: (07) 3308 6492

SA

Unit 2, 54 Grange Road, Welland SA 5007

Phone: (08) 8300 9600 Fax: (08) 8346 4076

WA

5/51-53 Kewdale Road, Welshpool WA 6105

Ph: (08) 9352 2400 Fax: (08) 9352 2458

Advertising