How to use the on-screen menus

Four kinds of information—menus, status displays, image control settings and battery voltage—can be displayed on the
screen.

Menu display

This display appears when the MENU/EXIT button is
pressed. If no further action is taken for the next 120
seconds, the display will be automatically cleared.
The position where the display appears on the screen can
be changed using the marker setting.
For details on the menu, refer to “MAIN MENU” (page 15).

[MAIN MENU]
MARKER 4
VIDEO CONFIG 4
SYSTEM CONFIG 4
OSD CONFIG 4
GPI 4
INPUT SELECT 4
CONTROL 4

EXIT SEL ENTER

1

MENU

XW

ENTER

Status display

The status display information is displayed under the
following conditions while the menu display is not on the
screen.

When the input signals have been switched

When the input channel has been changed

When no signals are supplied

The display location and display time can be changed using
the menu settings. When images are adjusted using the
image controls while the status display information is on the
screen, the display is cleared, and the settings adjusted by
the controls are displayed instead.

SDI1 1080/60I
CRCC
DC150V 60%

.

1

2

3

1 Channel and signal format

The channel which has been selected—whether SDI 1,
SDI 2, VIDEO, YPBPR or RGB—is displayed here.
Indicated as the signal format is the format of the signals
which have been input. However, “UNSUPPORTED
SIGNAL” will appear if signals which are not supported
have been input.
Similarly, “UNSUPPORTED SIGNAL” will also appear if
signals not selected as the FORMAT item setting on the
INPUT SELECT screen of the main menu are input even
when those signals are supported.
For details on the signals supported and format displays,
refer to page 12.

2 Warning display

This appears when an error has occurred or when a
special mode is being used.
CRCC

This indicates a CRCC error, and it appears
when the SDI signals contain an error.

FILM

This appears when the film mode (FILM) has
been selected as the GAMMA SELECT item
setting on the VIDEO CONFIG screen of the
main menu.
This appears when REMOTE has been
selected as the CONTROL item setting on the
CONTROL screen of the main unit. The
monitor controls will no longer function at this
time.

3 Battery voltage display

This indicates the voltage level of the battery. If an Anton
Bauer digital battery is being used, its remaining level is
indicated as a number of “∫” blocks and as a percentage
along with the voltage value.