Pitco Frialator Solstice I12 Water Cooker (Operations Manual) User Manual

Page 10

Advertising
background image

Solstice I12 Water Cooker Computer Service
Part #60153301

L20-316 Rev 0

10

3.4

Language Selection:

With display showing [PROGRAM], press the location key

.

Display shows [SELECT] [OPTIONS].

Press product key 4, display shows [ENGLISH] [LANGUAGE].

Use the location key

to scroll through choices (ENGLISH, ESPANOL, FRANCAIS,

DEUTSCH, HOLLAND).

Press

key to save choice. Display shows [PROGRAM].

3.5

Recovery Test Value:

This controller maintains a record of heat up times for the appliance. A poorly running appliance will
have increased recovery times stored in this display. There is no selection done here, just the display
of recovery time values.

With display showing [PROGRAM], press the product key

.

Display shows [SELECT] [OPTIONS].

Press product key 6; display will show [RECOVERY] [TEST].

Press the product key

. Display will show [FnnnLyyy], where nnn is the factory

recovery value, and yyy is the last warm up recovery value.

After recording these values, press the

key. Display returns to [PROGRAM].

3.6

Control or Timer:

With display showing [PROGRAM], press the product key

. Display shows [SELECT]

[OPTIONS].

Press product key 7; display will show [CONTROL].

Use the product key

to scroll through choices (Control, Timer).

Press

key to save choice. Display shows [PROGRAM].

Note: If timer is selected, heat control outputs are disabled, leaving only the timer functions active. For
normal appliance operation, this setting should be left on the “Control” setting.

Advertising