Characteristics – Philips TDA8783 User Manual

Page 8

Advertising
background image

2002 Oct 23

8

Philips Semiconductors

Product specification

40 Msps, 10-bit analog-to-digital
interface for CCD cameras

TDA8783

CHARACTERISTICS
V

CCA

= V

CCD

= 5 V; V

CCO

= 3 V; f

CLK

= 27 MHz; T

amb

= 25

°

C; unless otherwise specified.

SYMBOL

PARAMETER

CONDITIONS

MIN.

TYP.

MAX.

UNIT

Supplies

V

CCA

analog supply voltage

4.75

5

5.25

V

V

CCD

digital supply voltage

4.75

5

5.25

V

V

CCO

digital outputs supply voltage

2.5

3

5.25

V

I

CCA

analog supply current

78

95

mA

I

CCD

digital supply current

18

20

mA

I

CCO

digital outputs supply current

C

L

= 20 pF on all data

outputs; ramp input

1

mA

Digital inputs

C

LOCK INPUT

: CLK (

REFERENCED TO

DGND)

V

IL

LOW-level input voltage

0

0.8

V

V

IH

HIGH-level input voltage

2.0

V

CCD

V

I

IL

LOW-level input current

V

CLK

= 0.8 V

1

+1

µ

A

I

IH

HIGH-level input current

V

CLK

= 2.0 V

20

µ

A

Z

i

input impedance

f

CLK

= 27 MHz

46

k

C

i

input capacitance

f

CLK

= 27 MHz

1

pF

I

NPUTS

: SHP

AND

SHD

V

IL

LOW-level input voltage

0

0.8

V

V

IH

HIGH-level input voltage

2.0

V

CCD

V

I

IL

LOW-level input current

V

IL

= 0.8 V

6

µ

A

I

IH

HIGH-level input current

V

IH

= 2.0 V

0

µ

A

I

NPUTS

: SEN, SCLK, SDATA, OE, STDBY, CLPDM, CLPOB

AND

CLPADC

V

IL

LOW-level input voltage

0

0.8

V

V

IH

HIGH-level input voltage

2.0

V

CCD

V

I

i

input current

2

+2

µ

A

Correlated Double Sampling (CDS); note 1

V

i(CDS)(p-p)

CDS input amplitude pin 47
(peak-to-peak value)

400

1200

mV

I

CPCDS,

I

INP,

I

IND

input current pins 8, 46 and 47

2

+2

µ

A

t

CDS(min)

CDS control pulses minimum
active time

f

i(CDS1,2)

= f

CLK(pix)

;

V

i(CDS)(p-p)

= 600 mV

black-to-white transition in
1 pixel (

±

1 LSB typ.);

f

cut(CDS)

= 120 MHz;

f

cut(AGC)

= 54 MHz

8

ns

t

hd1

hold time INP compared to control
pulse SHP

see Fig.5

1

ns

Advertising