Page 4

Advertising
background image

2.0 Safety Devices

4

© Baxi Heating UK Limited 2010

2.1

Operation of Safety Devices

1. Your Promax FSB 30 HE is fitted with safety devices

which shut down the appliance if:

a) the system or boiler overheats.

b) the condensate drain is blocked.

c) there is no gas to the boiler.

2. The Flame Failure light ( ) will be either flashing or

permanently illuminated and the boiler will need resetting

(Fig. 3).

NOTE: In the case of persistent Flame Failure, shut

down the boiler (see Section 1.2) and consult your

Installer as an appliance or system fault is indicated.

2.2

Resetting

1. Allow the boiler to cool if hot.

2. Hinge down the facia cover.

3. Press the Reset Button (Fig. 3).

4. If the boiler will not reset see the LED Fault Indication
Label on the inside of the facia cover.

5. Further fault finding is described in Section 5.1 ‘Check
List.’

Low

High

Reset

Fig. 3

Reset Button

Flame Failure*

Facia Cover

Optional

Integral Timer

LED Fault Indication Label

*Flame Failure - Red Light
If the Flame Failure Light is ON press
the Reset Button. If Flame Failure occurs
persistently consult your Installer