Technical specifications electrical wiring, Compliance – POLAR G600 User Manual

Page 6

Advertising
background image

4

UK

Error Messages

The following table details the cause and subsequent response of the appliance to errors.

The alarm message will end when the alarm trigger is no longer present, except PF1 and PF2 that require the appliance to be turned Off, then On again.

Technical Specifications

Electrical Wiring

POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:

Live wire (coloured brown) to terminal marked L

Neutral wire (coloured blue) to terminal marked N

Earth wire (coloured green/yellow) to terminal marked E

All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.

Compliance

POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and
federal authorities.
POLAR products have been approved to carry the following symbol:

Error Message

(flashing)

Cause

Appliance Response

Action

HtA

The inner temperature exceeds
the set maximum temperature

Display flashes
Alternating error message and current temperature

Check Troubleshooting Guide
If problem persists call POLAR agent or
qualified Technician

LtA

The inner temperature exceeds
the set minimum temperature

Display flashes
Alternating error message and current temperature

Check Troubleshooting Guide
If problem persists call POLAR agent or
qualified Technician

PF1

Short circuit or interruption of
the thermostat probe input line

Display flashes

Compressor operates as specified by
parameter ‘=23’

PF2

Short circuit or interruption of
the evaporator probe input line

Display flashes

Defrost as specified by parameters d8 and d9

HLA

Inner temperature greater than
90°C

Display flashes
Alternating error message and current temperature

Call POLAR agent or qualified Technician

LLA

Inner temperature lower than
-45°C

Display flashes
Alternating error message and current temperature

Call POLAR agent or qualified Technician

Model

Voltage

Power

Current

Temperature

Range

Capacity

(litres)

Refrigerant

Dimensions

H x W x D (mm)

Weight

(Kg)

G596

230V 50Hz

340W

1.5A

-2°C to 10°C

282

R134a 240g

850 x 1360 x 700

98

G597

230V 50Hz

340W

1.5A

-2°C to 10°C

417

R134a 240g

850 x 1795 x 700

134

G598

230V 50Hz

450W

2A

-2°C to 10°C

563

R134a 250g

850 x 2230 x 700

153

G599

230V 50Hz

1000W

4.35A

-10°C to -20°C

282

R404 300g

850 x 1360 x 700

103

G600

230V 50Hz

1000W

4.35A

-10°C to -20°C

417

R404 260g

850 x 1795 x 700

136

G601

230V 50Hz

1000W

4.35A

-10°C to -20°C

563

R404 320g

850 x 2230 x 700

155

G621

230V 50Hz

340W

1.5A

-2°C to 10°C

417

R134a 240g

900 x 900 x 700

140

G622

230V 50Hz

340W

1.5A

-2°C to 10°C

368

R134a 250g

850 x 1365 x 700

107

U636

230V 50Hz

250W

1A

-2°C to 10°C

240

R134a 165g

850 x 900 x 700

70

U637

230V 50Hz

250W

1A

-2°C to 10°C

240

R134a 165g

850 x 900 x 700

71

U638

230V 50Hz

250W

1A

-2°C to 10°C

240

R134a 165g

850 x 900 x 700

72

Advertising
This manual is related to the following products: