COMPLETE SUBMERSIBLE SUMP PUMP INSTALLATION

Refer to the installation illustrations below and on the
following page for the following instructions. Be certain
sump basin is clean and all power to pump is shut off.
If pump fails to operate properly after installation, refer
to the troubleshooting checklist on page 6 or contact your

Thread male PVC adapter into pump
discharge opening.

Myers distributor. All parts with part numbers are
quality Myers parts.
Tools Needed for All Pump Installation
Pipe wrench, slot screwdriver, hacksaw, round file, drill,
1/8" drill bit, pvc cement.

Cement a 15" piece of PVC pipe to adapter. Use
appropriate diameter piping. Drill a 1/8" relief
hole in the pipe 5" above pump connection.
This hole prevents pump from air-locking.

Clamp Check Valve to top of 15" PVC pipe with
water flow arrow pointing away
from pump.

Lower pump into basin. Clamp needed PVC
discharge pipe and fittings to open end of
Check Valve.

Fill sump basin with water and plug in pump.
Perform several ON-OFF cycles to assure
satisfactory operation.