Connection terminal – Panasonic BM-ET330 User Manual

Page 14

Advertising
background image

14

Connection terminal

q Wiegand power (card reader)

Supplies power to a card reader.

w Wiegand GND (card reader)

This is the ground terminal for the power supply and
communication between the iris reader and a card
reader.

e Wiegand DATA0 (card reader)

A signal (DATA0) is input from a card reader to this ter-
minal.

r Wiegand DATA1 (card reader)

A signal (DATA1) is input from a card reader to this ter-
minal.

t Wiegand ACCEPT-LED (access control panel)

A signal (Wiegand ACCEPT-LED) is input to control the
ACCEPT indicator of this iris reader when Wiegand out-
put is set up.

y Wiegand power (access control panel)

The iris reader works even when nothing is connected
to this terminal.

u Wiegand GND (access control panel)

This is the ground terminal for communication between
the iris reader and an access control panel.

i Wiegand DATA0 (access control panel)

A signal (DATA0) is output from this terminal to an
access control panel.

o Wiegand DATA1 (access control panel)

A signal (DATA1) is output from this terminal to an
access control panel.

!0 Wiegand REJECT-LED (access control panel)

A signal (Wiegand REJECT-LED) is input to control the
REJECT indicator of this iris reader when Wiegand out-
put is set up.

!1 RS-485 (A) (access control panel)

A signal (RS-485 (A)) is input from or output to an
access control panel.

!2 RS-485 (B) (access control panel)

A signal (RS-485 (B)) is input from or output to an
access control panel.

!3 RS-485 (A) (card reader)

A signal (RS-485 (A)) is input from or output to a card
reader.

!4 RS-485 (B) (card reader)

A signal (RS-485 (B)) is input from or output to a card
reader.

!5 Alarm input1 (recognition start/buzzer)

An alarm signal is input to this terminal to start recogni-
tion or activate buzzer sound.

!6 Recognition result output1 (ACCEPT)

This terminal is activated when recognition is success-
fully completed.

!7 Recognition result output2 (REJECT)

This terminal is activated when recognition is not suc-
cessfully completed.

!8 Alarm output1 (power status)

This terminal is closed and low when power is supplied
from an external power-supply device to the iris reader.
The terminal is opened when the power supply is shut
down.

!9 Alarm output2 (tamper detection)

This terminal is activated when the iris reader enters the
"tamper detection" mode by the front/rear tamper detec-
tion switch (activated until the "tamper detection" mode
is cancelled).

@0 GND

This is the common terminal for the alarm output con-
nectors.

@1 Power input terminals

12 V DC (+12 V at the left/GND at the right) or 24 V AC

q

@1

w
e
r
t
y
u
i
o

!0

!6
!7
!8
!9
@0

!1
!2
!3
!4
!5

Pin No.

Advertising