PowerPack 1500 MKII

AVR Boost Range sets the range at which the UPS will switch over to battery
when the utility presents an undervoltage situation.

• Press and hold the main off switch “ ” to select the AVR Boost Range Setting
mode.

• Press and hold the main on switch “I” for more than 3 seconds to select differ-
ent AVR boost ranges.

2.6.4.4 AVR Boost

Range Setting

AVR Boost Range mode

All Level LEDs off

AVR Boost = -25%

5th Level LED on

AVR Boost = -20%

6th Level LED on

AVR Boost = -30%