Multi-server card & relay interface cards, Expansion chassis & modbus, Card – Powerware 9120 User Manual

Page 22

Advertising
background image

Powerware

Single- and Three-phase Connectivity Products

Features and Benefits

• Creates a wide array of

communication options for
Powerware UPS products
by acting as the framework
for protocol conversion via
compatible X-Slot cards for
Modbus, SNMP, and HTTP

• Adds expanded communica-

tion support for a wide range
of UPSs: Powerware 5115RM,
5125, 9120, 9125, 9170+,
9315, 9320, and 9335

• Offers flexible mounting options

via included feet, rackmount,
and wall-mount kits

• Speeds corrective action by

providing alarm notification
through any combination
of email, SNMP traps, or
NetWatch network messages

• Compatible with the following

X-Slot cards:

- Modbus (one included)–
Connect to another Modbus

network or monitor via
Building Management
System (BMS)

- Powerware ConnectUPS-X

SNMP/Web card

- Powerware ConnectUPS-M

SNMP card

- Single-Port Serial Card
- Multi-Server Card

Multi-Server Card &

Relay Interface Cards

Out-of-band communica-

tion and notification of

UPS alarm status

Expansion Chassis

& Modbus

®

Card

Increasing the flexibil-

ity and effectiveness

of power protection

systems

Features and Benefits

Multi-Server Card
• Provides out-of-band communi-

cation methods via RS-232
serial communication or
isolated Form-C relay contacts

• Connects up to three servers

for monitoring and graceful
shutdown

• Supports Load Segment con-

trol and RS-232 signals for low
battery and AC Fail

Relay Interface Card
• Increases reliability and system

availability

• Provides isolated dry contact

Form-C relay outputs for utility
failure, low battery, UPS alarm/
OK, and on bypass

• Is user-selectable for normally-

open (NO) or normally-closed
(NC) contacts

• Enables remote shut down of

the UPS

• Comes equipped with DB-15

output connection and terminal
block outputs on X-Slot model

• Adapts to IBM iSeries

®

(AS/400

®

) applications with

optional cables

• Works with the following

Powerware UPS products:
Powerware 5115RM, 5125,
9120, 9125, 9155, 9170+, 9320,
and 9315

20

EATON CORPORATION Powerware Product Catalog

The Multi-Server Card provides out-of-band serial communication
with LanSafe software when Ethernet connectivity is not available
or required. Load Segment control is mapped to specific serial ports
on the card to provide selective control over critical loads. The Relay
Interface Cards provide simple alarm notification via isolated contacts
to signal remote annunciation panels or security systems in the event
of a change of state in UPS operation.

The Expansion Chassis is a three-slot peripheral device that
expands communication methods for a UPS through its support for
additional X-Slot cards. The Expansion Chassis is pre-configured
with the Powerware Modbus Card, which serves as the interface to
Modbus networks and as the integral communications controller for
the remaining two slots.

Advertising
This manual is related to the following products: