The following is a basic formula to be used as a guide to determine current
draw. A 50% amplifier efficiency rating is used as an average. Your new
POWERCLASS

amplifier is more efficient, other amplifiers will probably

be less. This formula is to be used as a guideline. Using wire of a larger
gauge can only improve the current transfer of your system. Do not use
smaller gauge wire.

Total RMS output x 2 = Total Input Wattage

Total Input Wattage = Current Draw (in Amps)
Supply Voltage

Example: A

POWERCLASS

4400 amplifier has four channels at 50 watts

RMS per channel into 4 Ohms (50 x 4 = 200). You would use the
formula in the following way:

200W x 2 = 400W

400W = 33.3A Total current draw.

12V

If the same amplifier is driven into a 2 Ohm stereo or 4 Ohm mono load,
double it's 4 Ohm RMS rating. All

POWERCLASS

amplifiers will effectively

double their power at this load.

100W x 4 x 2 = 800W

800W = 66.6A Total current draw.

12V

If you are using more than one amplifier, add up the total current draw
for all of them and choose the appropriate gauge based on the grand total.

P o w e r W i r e C a l c u l a t o r

Recommended MINIMUM Gauge

Total Current Draw

Length Of Wire To Be Run

( in Amps)

Up to 4ft. 4 to 7ft.

7 to 10ft. 10 to 13ft. 13 to 16ft. 16 to 19ft. 19 to 22ft. 22 to 28ft.

0-20

14

12

12

10

10

8

8

8

20-35

12

10

8

8

6

6

6

4

35-50

10

8

8

6

6

4

4

4

50-65

8

8

6

4

4

4

4

2

65-85

6

6

4

4

2

2

2

0

85-105

6

6

4

2

2

2

2

0

105-125

4

4

4

2

2

0

0

0

125-150

2

2

2

2

0

0

0 00

(

NOTE: The ground wire should be the same gauge as the power wire.