Specifications – Philips LTC0600 User Manual

Page 10

Advertising
background image

English

17

16

10

Specifications

AGC:

18 dB

Selectable

2

):

24 dB

Automatic shutter:

up to 1/100,000 sec.

Selectable

2

):

ON, OFF, Flickerless

Manual shutter:

1/60 up to 1/10,000

Selectable

2

):

Auto Black:

ON, OFF

Selectable

2

):

Black level:

15 fixed levels

Contouring:

H and V symmetrical,

Selectable

2

):

15 fixed levels, Automatic and OFF

Compression:

White Compression

Selectable

2

):

15 fixed levels and OFF

Gamma:

Contrast Enhancement

Selectable

2

):

15 fixed level, 0.25 up to 1

White Balance:

Auto sensing (TTL)

Auto AWB:

2700 K to 10,000 K

Auto store:

2700 K to 10,000 K

Video Output

Video output 1:

BNC isolated from mechanical earth, 75 Ω, AC coupled,
nominal 1 V[

p-p

] Pal or NTSC composite,

Video output 2:

4 pin S-VHS connector 75 Ω, AC coupled
S-VHS. Level: Y 1 V[

p-p

], C, 300 m V[

p-p

]. or

Selectable

2

):

Balanced output. 2 V[

p-p

] into 150 Ω. Unbalance -20 dB at 5 MHz

Synchronization:

Internal crystal reference, Line-locked, H/V-lock, ext V-lock

Sync. Input

BNC isolated from mechanical earth

Input impedance:

Selectable

2

): 75 Ω or >10 kΩ AC coupled

External H/V lock:

Nominal CVBS 1 V[

p-p

] (min. 150 mV, max. 600 mV)

External V-lock:

Positive V-pulse, 8%-50% duty cycle, Standard 5 V, Cmos level

Capture time:

≤2 s.

Serial Input/Output:

Sub D, 9-pole connector, RS 232 Selectable

2

): 1200, 2400,

4800 baud. Connector pinnings:TX=2, Rx=3, Ground=5

User input:

Switch to Mode 3, Mode select input=1, Ground=5. Pull-up
10 kΩ to +5V

Selectable

2

):

Active low or active high or disable.

2

) Selection by PC software LTC0650/00

9.2.7 Linelock Phase
This function is active when the camera operates in linelock mode.

9.2.8 H Phase
This function is active when the camera operates with external synchronisation (H+V).
Use the H-phase setting to adjust Horizontal timing differences when cameras are H-V
synchronised. Input standard CVBS synchronisation signals.

9.2.9 ext V Phase
This function is active when the camera operates with external synchronisation.
(External V)
Use the extV phase setting to adjust V phase differences when cameras are used in a
system. Input; Positive V-pulse, 8-50% duty cycle, 5 V CMOS level.

LTC 0600/10 models, PAL
Pick-up Device:

752 (H) x 582 (V) active pixels, Interline Transfer CCD.

Scanning Area:

7.95 (H) x 6.45 (V) mm. Equivalent to 1/2” diagonal scanning area.

Scanning PAL:

625 lines / 50 fields / 25 frames, interlaced

Horizontal:

15.625 kHz

Vertical:

50 Hz

LTC 0600/20 models, NTSC
Pick-up Device:

768 (H) x 494 (V) active pixels, Interline Transfer CCD.

Scanning Area:

7.95 (H) x 6.45 (V) mm. Equivalent to 1/2” diagonal scanning area.

Scanning PAL:

525 lines / 60 fields / 30 frames, interlaced

Horizontal:

15.734 kHz

Vertical:

60 Hz

Horizontal Resolution: 480 TVL
MTF:

≥ 45 % at 4 MHz

Sensitivity:

Usable Picture

Full Video

Scene illumination:

1

)

fc

0.03

0.17

lx

0.3

1.7

Imager illumination:

fc

0.003

0.02

lx

0.03

0.2

1

) for f/1.2 lens, 89% scene reflectance and 18 dB AGC

Signal-to-Noise:

50 dB at 1.7 lux (0.17 fc) sensor illumination
(Unified weighting filter in accordance with CCIR Rec. 567)

Advertising