Centronics parallel interface signals – Printronix L1524 User Manual
Page 118

B–2
Host I/O Interfaces
Table B–1. Centronics Parallel Interface Connector Pin Assignments
Input Signals
Output Signals
Signal
Pin
Signal
Pin
DATA LINE 1
2
Return
20
ACKNOWLEDGE
10
Return
28
DATA LINE 2
3
Return
21
SELECT
13
Return
28
DATA LINE 3
4
Return
22
PAPER EMPTY
12
Return
30
DATA LINE 4
5
Return
23
BUSY
11
Return
29
DATA LINE 5
6
Return
24
NFAULT
32
Return
33
DATA LINE 6
7
Return
25
PRIME
31
Return
30
DATA LINE 7
8
Return
26
DATA LINE 8
9
Return
27
PAPER INST
15
Return
29
Chassis GND
17
+ 5 Volts
18
DATA STROBE
1
Return
19
Centronics Parallel Interface Signals
The Centronics interface signals are defined below.
PAPER EMPTY – A high true level from the printer to indicate the printer is in a
fault condition.
SELECT – A high true level from the printer to indicate the printer is ready for
data transfer and the ON LINE switch has been activated.
BUSY – A high true level from the printer to indicate the printer cannot receive
data.