Psiber Data Systems NETWORK IP TESTER User Manual

Page 7

Advertising
background image

The information is retained even if the unit is turned off or the batteries are

removed. To remove an entry from the list, press the right cursor key to

select the entry and then press the star key. A “Delete Entry” message is

displayed and pressing the SAVE function key clears the selected name

and IP Address.

PINGER IP SETUP SCREEN

The IP address for the Pinger is input from this screen. The Pinger

comes programmed with a default address of 192.168.42.1. The Pinger

IP address is changed as described in the Data Entry section.

POWER DOWN SETUP SCREEN

The Pinger will automatically turn off after the time selected in the

Power Down Setup screen.

Settings available are five minutes, fifteen minutes, thirty minutes and on

(must be turned off manually). Press the SAVE function key to store the

selected setting.

SUBNET MASK SETUP SCREEN

To Ping an IP address in a subnet different than the subnet of the

Pinger, requires that the Subnet Mask be entered and “ON” and the
appropriate Gateway IP address has been entered. Mask “ON” and

OFF” is selected with the Up/Down Cursor key. The Mask is entered

as described in the Data Entry section. A zero in the first field is an

invalid mask entry and the Pinger defaults to 255 when the mask is

saved.

NOTE: Subnet Mask and Default Gateway IP address may be found by

going to a computer on the subnet where the Pinger will be used, open

the Windows Control Panel, open the network icon, open the LAN Icon,

select TCP/IP Protocol and then select properties.

GATEWAY SETUP SCREEN

The IP address for the default Gateway (typically a router or a

server) is input from this screen.

Pinger MAC SCREEN

The Pinger MAC address is displayed in this screen. The MAC for

each Pinger is unique and can not be changed. See Note in DHCP.

Advertising