4.2.7 Line

You can access the onboard configuration program by attaching a VT100 compatible device to the Managed Switch’s serial

console port. Management access through the console port is controlled by various parameters, including a password, timeouts,

and basic communication settings. These parameters can be configured via the Web or CLI interface.

This section has the following options:

■ Console

Sets console port connection parameters

■ Telnet

Sets Telnet connection parameters

4.2.7.1 Console Port Settings

Specify the console port connection parameters as required, then click Apply. The Console Port Settings screen in

Figure

4-2-15

appears.

Figure 4-2-15 Console port settings screenshot

The page includes the following fields:

Object

Description

• Login Timeout

Sets the interval that the system waits for a user to log into the

CLI. If a login attempt is not detected within the timeout interval, the connection is

terminated for the session.

Range: 0-300 seconds;

Default: 0 seconds

• Exec Timeout

Sets the interval that the system waits until user input is detected. If user input is

not detected within the timeout interval, the current session is terminated.